Products

  • GDCR3000 Digital Earth Resistance Tester

    GDCR3000 Digital Earth Resistance Tester

    It is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement.

  • GDHX-9500 Phase Detector

    GDHX-9500 Phase Detector

    GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement.

  • GDHX-9500B High Accuracy Phase Detector for Electrical Systems

    GDHX-9500B High Accuracy Phase Detector for Electrical Systems

    GDHX-9500B Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection,  phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.

  • GDJR-200D Single Phase Electronic Thermal Relay Calibrator

    GDJR-200D Single Phase Electronic Thermal Relay Calibrator

    GDJR-200D Single Phase Electronic Thermal Relay Calibrator is mainly used for the setting and verification of various electrical equipment. With features of reasonable design, convenient operation and large output power, it is widely used in electric test sites of power system, railway, petrochemical, metallurgy and mining enterprises.

     

  • GDJB-II Secondary Current Injection Test Set

    GDJB-II Secondary Current Injection Test Set

    GDJB-II type Single Phase Relay Protection Tester is the updated calibration device for relay testing. It shows clear data,operation is easy.

     

  • GDJB-1200A Six Phase Relay Protection Test Set

    GDJB-1200A Six Phase Relay Protection Test Set

    GDJB-1200A Six Phase Relay Protection Microcomputer Test Device plays a key role in operating electricity power systems reliably and safely. It is the testing device used in professional field of microcomputer protection, relay protection, excitation measurement, fault recorder.

     

  • GDJB-802 Three Phase Secondary Current Injection Relay Test Set

    GDJB-802 Three Phase Secondary Current Injection Relay Test Set

    GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. 

     

  • GDYZ-302W Metal Oxide Arrester (MOA) Tester

    GDYZ-302W Metal Oxide Arrester (MOA) Tester

    GDYZ-302W Metal Oxide Arrester Tester is is composed of a host, a detector, and an insulating rod. The host and the detector adopt wireless communication, the communication distance is 30 meters, the host can remotely open or close the clamp head of the detector to complete the test process, and the host can display the current test value and the status of the clamp head in real time. The detector uses a micro motor to drive the opening or closing of the clamp head. The clamp head is made of high-performance permalloy, which has super anti-interference ability and is hardly affected by external magnetic fields. The resolution is as high as 1uA. The detector can be connected to an insulating rod for testing of zinc oxide surge arresters on high-voltage lines. The meter can also be used as an ultra-high-precision clamp-on leakage current meter.

  • GD-610B Insulator Faults Detector

    GD-610B Insulator Faults Detector

    The model GD-610B is used to detect faults of insulators and locate the faults in power station, substation without cutting power. It also can be used for PD detection, corona discharge detection, discharge detection of electric equipment.

     

     

     

  • GDJW-40B Wireless Insulator Tester

    GDJW-40B Wireless Insulator Tester

    GDJW-40B can be used to test the distribution voltages of the charged suspended insulator or the laboratory detection of the suspended insulator, and enable to effectively detect the internal hidden trouble of the insulator, improve the operating reliability of the power grid system, and improve the working efficiency of the line staff who carries out the live testing.

     

  • Online Monitoring System for Metal Oxide Arrester

    Online Monitoring System for Metal Oxide Arrester

    There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection.

  • GDYZ-301 Zinc Oxide Surge Arrester Tester

    GDYZ-301 Zinc Oxide Surge Arrester Tester

    GDYZ-301 Lightning Arrester Tester is the special equipment of testing zinc oxide arrester electric performance. It is suitable for testing various voltage levels zinc oxide arrester with or without electricity, thus to detect hazards inside the device caused by wet insulation or metal oxide varistor (MOV) aging.

     

Send your message to us:

Write your message here and send it to us