Products

  • GDKS-205A Automatic Flash Point Open Cup Tester

    GDKS-205A Automatic Flash Point Open Cup Tester

    GDKS-205A automatic open cup flash point tester is the device testing open cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department.

  • GDHG-106B CT/PT Analyzer

    GDHG-106B CT/PT Analyzer

    GDHG-106B is a multifunctional tool specially designed for analyzing current transformers and voltage transformers of protection or measurement use. The operator only needs to set values for test current and voltage, the instrument will automatically boost voltage and current, and then show test results in a short time. Test data can be saved, printed, and uploaded to PC through USB interface.

  • GDWG-IV SF6 Gas Leak Detector(IR Series)

    GDWG-IV SF6 Gas Leak Detector(IR Series)

    GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. 

  • GDWG-V SF6 Gas Leak Detector (IR type, Double display)

    GDWG-V SF6 Gas Leak Detector (IR type, Double display)

    GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration.

  • GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer

    GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer

    At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad. 

  • GDSF-411CPD SF6 Gas Comprehensive Analyzer

    GDSF-411CPD SF6 Gas Comprehensive Analyzer

    GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product.

  • GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD 3-In-1 SF6 Gas Analyzer

    GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP®  series sensors produced by Finland Vaisala company. 

  • GDZRC-20U Series DC winding resistance tester

    GDZRC-20U Series DC winding resistance tester

    GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
    It has the features of fast measurement, small size and high accuracy of measurement, which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.

     

  • GDZRC-40A Series DC Winding Resistance Tester

    GDZRC-40A Series DC Winding Resistance Tester

    GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.

     

     

     

  • GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester

    GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester

    GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.

     

  • GDZRC-50U DC Winding Resistance Tester

    GDZRC-50U DC Winding Resistance Tester

    GDZRC-50U DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.

  • GDZRC-100U Transformer DC Winding Resistance Tester

    GDZRC-100U Transformer DC Winding Resistance Tester

    Transformer DC winding resistance is a required test item for the factory test, installation, overhaul, change of tap switch, handover test and preventive test of power department.